Description
IS420PUAAH1A – Quad Core Controller is available in stock which ships the same day.
IS420PUAAH1A – Quad Core Controller comes in UNUSED as well as REBUILT condition.
To avail our best deals for IS420PUAAH1A – Quad Core Controller, contact us and we will get back to you within 24 hours.
The IS420PUAAH1A controller is the second of the UCSC controllers in the Mark VIe Series, this controller can be used with a ControlST version of 07.01 or later and can be used with embedded EtherCAT, embedded PPNG, and EFA configurations. All information provided can be found in the GEH-6855 Volume I and II manuals. The IS420PUAAH1A is a later revision of the UCSC controller and has features not provided by the prior model IS420UCSCH1A.
IS420PUAAH1A Other names:
Signal unit module IS420PUAAH1A
IS420PUAAH1A Input/Output Module
Editable Control IS420PUAAH1A
Part Number : | IS420PUAAH1A | Product Family: | Mark VIeS Functional Safety System |
Product Name : | Mark VIe Gateway Controller | Manufacturer (OEM): | GE Power |
Platform Configuration Supported Features | EFA, Embedded EtherCAT, and Embedded PPNG | Altitude for Normal Operation | 0-1000 m at 101.3 to 89.9 kPa |
Product Description
The IS420PUAAH1A Quad-Core Controller is another version of the UCSC controller that has a quad-core and operates on 1.2 GHz AMD G-Series. This controller was designed by General Electric to be used in the Mark VIe Series. This controller is the main controller mentioned in the GEH-6855 Volume II manual and is described as being a real-time hypervisor controller with a QNX Neutrino multi-task capable operating system. The QNX operating system is used in highly-reliable high-speed industrial applications. Another type of technology used on this controller is Embedded Field Agent (EMA) technology which helps apply Predix cloud-based applications and potentially web applications over a stable connection, all of these working together allows for real-time data to be delivered to the connecting controllers. Compared to the other controllers in the Mark VIe Series that have all of the input-outputs coming through the backplane the IS420PUAAH1A controller does not use the backplane and does not host any I/O applications. The software and hardware architecture used with this controller will guarantee that no individual point of application input will be lost if a controller must be shut down for repair or maintenance.
The IS420PUAAH1A controller has a variety of different ports used for Ethernet Interfacing, there are three of the ports which are each used for different redundancy applications. When being used in a TMR redundant applications all three ports will be used, whereas in dual redundant applications only the S/SL2 and R/SL1 ports will be used. The RJ45 connector and 10Base-TX/100Vase-TX twisted pairing are used with the ports in any redundancy application.
Functional Description
IS420PUAAH1A is a Quad Core Controller manufactured and designed by General Electric. It is a part of the Mark VIe Series used in GE Distributed Control Systems. It is a version of the quad-core controller that is used with the QNX Neutrino operating system. TMR, Simplex, and Dual redundancy are supported by the component. The QNX operating system is used in high-speed, highly reliable industrial applications. Another type of technology used on this controller is Embedded Field Agent (EMA) technology, which allows Predix cloud-based applications and possibly web applications to be applied over a stable connection, allowing real-time data to be delivered to the connecting controllers.
IS420PUAAH1A Features
The controller comes with 4 GB of DDR3-1333 SDRAM, which is a type of memory used in computers and other digital devices for high-speed data storage. The controller has 5 Ethernet ports, which allow it to connect to other devices and networks for data transfer and communication. The controller uses ControlST as its Human-Machine Interface (HMI), which is a software application used to interact with and control the device.
The Mark VIe quad-core controller runs high-speed, high-reliability industrial applications using real-time hypervisor technology and QNX Neutrino, a real-time, multi-tasking operating system (OS). PredixTM cloud-based apps and/or locally hosted web applications are applied through a secure connection and delivered real-time data using embedded field agent (EFA) technology.
A software package tailored to the UCSCH1x controller’s use is preloaded. It leverages IONet interfaces as a turbine or balance of plant (BoP) controller and runs Mark VIe firmware and applications. Only supporting Mark controls I/O packs and controllers, IONet is a private special-purpose Ethernet. To synchronize the clocks of the I/O modules and controllers to within 100 microseconds, IEEE 1588 protocol is employed through the IONet interfaces.
With the IONet connections, external data is transmitted to and from the controller’s control system database. To the I/O modules, this also refers to process inputs and outputs. The UCSC controller lacks any application I/O, in contrast to conventional controllers that host application I/O on a backplane.
Operation
The operation of the system involves several key aspects, including the installation of the ToolboxST application, configuring the UDH network communication, and establishing the necessary IP address for communication with site HMIs. Here is an expanded explanation of these operations:
ToolboxST Application Installation: To facilitate configuration and management tasks, the ToolboxST application is typically installed on a minimum 4 GB unencrypted flash drive. This flash drive serves as the storage medium for the application and contains the necessary files and settings. The ToolboxST application provides a user-friendly interface for configuring various aspects of the system, including network communication.
UDH Network Configuration: The UDH (User Datagram Header) network is utilized for communication within the system. During the configuration process, the ToolboxST application is employed to define the communication parameters for the UDH network. This involves setting up network addresses, ports, protocols, and other relevant settings. The configuration ensures that the control module can establish reliable and secure communication with other devices and systems within the network.
Default IP Address: By default, the control module is assigned the IP address 192.168.101.111. This IP address serves as the initial configuration for the module’s network connectivity. However, it is important to note that this default IP address may need to be modified to match the specific requirements and setup of the site or network where the system is deployed.
Configuring Relevant UDH IP Address: In order for the control module to effectively communicate with the site HMIs (Human-Machine Interfaces), it must be configured with the relevant UDH IP address. This IP address is specific to the UDH network and enables seamless communication between the control module and the site HMIs. Through the ToolboxST application, the control module’s IP address can be customized and set to the appropriate value that aligns with the network configuration and addressing scheme of the site.
Virtual Network
The virtual network feature in controllers is a powerful capability provided by the hypervisor, enabling seamless communication and data exchange between virtual machines (VMs) running on the same physical machine or across multiple physical machines in the network. The virtual network functions similarly to a conventional Ethernet network, facilitating data transmission between VMs just as physical Ethernet networks facilitate data transfer between physical machines.
Virtual network plays a crucial role in connecting different components of the system and enabling efficient data transfer. Specifically, it facilitates data exchange between the Embedded Field Agent (EFA) and the Mark VIe control, both of which run as separate VMs on the UCSCH1 controller.
Here’s how the virtual network enables data communication between the EFA and the Mark VIe control:
EFA and Mark VIe Control VMs: In the UCSCH1 controller, the EFA and the Mark VIe control are both running as virtual machines (VMs) within the same hypervisor environment. Each VM operates independently, emulating separate computing environments within the same physical machine.
Data Transfer through Virtual Network: When data needs to be exchanged between the EFA and the Mark VIe control, it is transmitted through the virtual network provided by the hypervisor. The virtual network efficiently routes the data between the two VMs, enabling seamless and fast communication.
Connection to the Cloud: The EFA, being an essential component for remote monitoring and management, requires a connection to the cloud for data exchange with remote servers or cloud-based applications. This connection allows the EFA to send data to the cloud and receive commands or updates from the cloud-based systems.
Physically Managed Switch for Network Division: To maintain proper network segregation and security, a physically managed switch is used to divide the networks. The physically managed switch creates distinct network segments, ensuring that the Mark VIe control, which contains sensitive control data, remains isolated from the cloud network. This network division helps protect critical control systems from potential external threats.
By leveraging the virtual network, the controller achieves efficient and secure data communication between its different VMs, enabling seamless coordination and control of various components in the system. The integration of a physically managed switch adds an extra layer of security, ensuring the safety and integrity of critical control systems while allowing the EFA to establish connections with cloud-based systems for enhanced functionality and remote monitoring capabilities.
Ethernet Ports/Controller Communications Support
3 IONet ports (R/S/T) for I/O module communications (simplex, dual, TMR, and Shared I/O supported).
ENET 1 – EGD/UDH communications to ToolboxST PC, HMIs, UCSCS2A Safety controller, and GE PACSystems products.
Modbus TCP Slave, Read/Write.
ENET 2 – Secondary UDH communications, Modbus TCP Slave and OPC UA.
IICS Cloud port for Embedded Field Agent (EFA).
Module Ports
The control module is equipped with various ports on its front and bottom panels, serving different purposes and enabling connectivity and functionality. Here is an expanded explanation of each port:
Ethernet Ports: The front panel of the module features five Ethernet ports. These ports are used for establishing network connections and enabling communication with other devices or systems within the network.
Predix Connectivity Port: Located on the bottom panel, this Ethernet port is specifically designated for connectivity to Predix, a cloud-based platform developed by GE. It facilitates data exchange and integration with Predix for enhanced monitoring and analytics capabilities.
USB Ports: The module has two USB ports, which are primarily used for specific functions. These ports are typically utilized during the initial setup of the UDH (User Datagram Header) network IP address. Additionally, they can be utilized for a restore function, allowing for the restoration of the module’s configuration or software.
COM Port: The COM port is a serial communication port that employs an RJ-45 connector and operates at a speed of 115200 bits per second (bit/s). The configuration for this port is 8N1, which denotes eight data bits, no parity bit, and one stop bit. This port does not employ flow control and is commonly used by GE for troubleshooting purposes in the field. It supports the serial redirection of UEFI-setup, facilitating configuration adjustments and troubleshooting activities.
Display Port: The module features a Display Port, although it is disabled after the system’s startup. The Display Port is typically used to connect an external display device for video output, but its functionality is limited or deactivated once the module is operational.
microSD Port: While the module includes a microSD port, it is not currently supported. The microSD port is designed to accommodate a microSD card, which can be utilized for storage purposes. However, in this particular system, the functionality of the microSD port is not enabled or actively supported.
Product Attributes
Altitude for Normal Operation: Designed to operate within an altitude range of 0-1000 meters. It can function reliably in environments with varying atmospheric pressure, ranging from 101.3 to 89.9 kilopascals (kPa). This attribute ensures that the module can maintain optimal performance even at different altitudes.
Dimensions with Mounting: The module has specific dimensions when considering its mounting. It has a height of 8.03 inches, a depth of 5.99 inches, and a width of 2.17 inches when properly mounted. These dimensions provide guidance for installation and integration into the overall system architecture.
HMI (Human-Machine Interface): Supports ControlST V07.00.00C or later as its human-machine interface. The HMI facilitates interaction between the module and the human operator, allowing for intuitive control, monitoring, and configuration of the system.
Memory Type: The module is equipped with 4 GB DDR3-1333 SDRAM memory. This type of memory is commonly used for storing and processing data within the module. The 4 GB capacity provides sufficient space for efficient data management and enables the module to handle complex control algorithms and calculations effectively.
Number of Ethernet Ports: Features a total of six Ethernet ports. Five of these ports are located on the front panel, providing convenient access for networking purposes. Additionally, one Ethernet port is available on the bottom of the module, specifically designed for Predix connectivity. These Ethernet ports facilitate seamless communication and data exchange between the module and other devices or systems within the network.
NVSRAM (Nonvolatile Static Random-Access Memory): The module incorporates NVSRAM, which includes 3067 nonvolatile program variables, 64 totalizers, and 338 forces. NVSRAM allows the module to retain critical information, such as program variables and configuration settings, even during power outages or system failures. This attribute ensures data integrity and reliability, crucial for applications where data loss is not acceptable.
Platform Configuration Supported Features: Supports EFA (Embedded Functionality Automation), Embedded EtherCAT (Ethernet for Control Automation Technology), and Embedded PPNG (Predix Process & Notification Gateway) as its platform configuration features. These advanced networking capabilities enhance the module’s connectivity, compatibility, and overall performance in complex industrial control systems.
Storage Temperature: The module is designed to withstand a wide range of storage temperatures, from -40 to 85 degrees Celsius. This attribute allows the module to be stored safely in environments with extreme temperature conditions, ensuring its durability and long-term reliability.
Diagnostics
The Control Module’s circuit cards include system (software) limit checking, high/low (hardware) limit checking, and comprehensive diagnostics for abnormal hardware conditions. System limit checking consists of two limits for each analog input signal, which can be set with the I/O Configurator in engineering units for high/high, high/low, or low/low.
Each input limit can be configured for latching/non-latching and enable/disable. System limit checking logic outputs are generated per frame and stored in the database (signal space) for use in control sequencing and alarm messages. Each analog input has high/low (hardware) limit checking, with typically two occurrences required before an alarm is triggered.
These limits are not programmable and are chosen to be outside the normal control requirements range but within the linear hardware operational range (before the hardware reaches saturation). The software maintenance tools provide access to diagnostic messages for hardware limit checks and all other hardware diagnostics for the card (Control System Toolbox). In the database, each card has a composite logic output, and another logic output indicates a high/low (hardware) limit fault of any analog input or the associated communications for that signal.
Characteristics
HMI: ControlST – The human-machine interface (HMI) used in this system is ControlST. ControlST is a software or hardware component that allows users to interact with and control the system.
Trip Solenoid Rating: 125 V dc – The trip solenoid used in the system has a rating of 125 volts direct current (V dc). The trip solenoid is an electromechanical device that is used to trip or close circuit breakers or other devices in response to specific conditions.
Span: -8 mV to +45 mV – The span refers to the range of values that can be measured or controlled. In this case, the system has a span of -8 millivolts (mV) to +45 mV. This indicates that the system can measure or control signals within this voltage range.
Power supply voltage: 28 V dc – The power supply voltage for the system is 28 volts direct current (V dc). This voltage is used to provide power to the various components of the system.
Voltage Range: 18 – 32 VDC – The system operates within a voltage range of 18 to 32 volts direct current (VDC). This indicates that the system is designed to function properly within this voltage range.
Platform Configuration Supported Features: EFA, Embedded EtherCAT, and Embedded PPNG – The platform configuration of the system supports several features, including EFA (Electronic Function Blocks), Embedded EtherCAT (Ethernet for Control Automation Technology), and Embedded PPNG (Powerful Programmable Numeric Gateway). These features enhance the system’s capabilities and functionalities.
NVSRAM: 3067 Nonvolatile Program Variables, 64 Totalizers, and 338 Forces – The system has NVSRAM (Nonvolatile Static Random Access Memory) that can store 3067 nonvolatile program variables, 64 totalizers, and 338 forces. NVSRAM is a type of memory that retains its stored information even when power is removed from the system.
Number of Ethernet Ports: 6 – The system is equipped with six Ethernet ports. Ethernet ports are used for connecting the system to a network, allowing for communication with other devices or systems.
Altitude for Normal Operation: 0-1000 m at 101.3 to 89.9 kPa – The system is designed to operate normally within an altitude range of 0 to 1000 meters. The atmospheric pressure range for normal operation is 101.3 to 89.9 kilopascals (kPa).
HMI: ControlST V07.00.00C or Later – The specific version of the ControlST HMI used in the system is V07.00.00C or later. This indicates the minimum version requirement for compatibility and functionality with the system.
Cable Separation and Routing
When it comes to cable separation and routing in control systems, it is important to consider certain factors to ensure optimal system performance. One significant consideration is the prevention of electrical noise interference caused by different voltage levels in the cabling. Electrical noise can disrupt the operation of microprocessor-based control systems, leading to malfunctions or unreliable performance.
To mitigate the risks associated with electrical noise interference, it is essential to follow proper guidelines and recommendations during the installation of cables. Before proceeding with the cable installation, it is advisable to consult the relevant manuals and documentation provided by the manufacturer or system designer. These manuals often contain specific instructions and precautions for cable installation in various scenarios. If the installation site presents unique circumstances or if the guidelines mentioned in the documentation cannot be met, it is crucial to seek further guidance or clarification.
During the planning stages of system revamps or upgrades, adherence to level rules is highly recommended. Level rules refer to established standards and guidelines for cable separation and routing in control systems. These rules ensure that cables are appropriately organized and spaced to prevent interference and optimize system performance. By considering level rules during the planning process, the chances of a trouble-free installation and proper application of the control system are significantly increased.
By following these guidelines and best practices, potential issues arising from electrical noise interference can be minimized. Proper cable separation and routing help maintain the integrity of the control system, ensuring reliable and efficient operation. It is important to prioritize these considerations during the design, installation, and maintenance phases to maximize the performance and longevity of the control system.
Environment Features
The Mark VIe control system cabinet should be installed in an environmentally controlled room or in the control room itself. The cabinet should be installed in a location where the floor surface allows for attachment in only one plane (a flat, level, and continuous surface).
The mounting hardware is supplied by the customer. Lifting lugs are provided, and lifting cables must not exceed 45° from the vertical plane if used. Finally, the cabinet has a door handle that can be locked for security. Interconnecting cables can enter the cabinet from the top or bottom via removable access plates.
Convection cooling of the cabinet necessitates the sealing of conduits to access plates. Furthermore, the temperature of the air passing through the conduit must be within the acceptable range. This is true for both the top and bottom access plates.
FREQUENTLY ASKED QUESTIONS
What is IS420PUAAH1A ?
It is a Quad Core Controller manufactured and designed by General Electric
What is the memory capacity of the component?
The memory capacity of the component is 4 GB DDR3-1333 SDRAM.
How many Ethernet ports does it have?
It has 5 Ethernet ports.
What is the trip solenoid rating of UCSCH1B?
The trip solenoid rating is 125 V dc.
What is the voltage range of the board?
The voltage range is 18 – 32 VDC.
What is the mounting option for the module?
The mounting option for the component is DIN-rail mounting.
All products on this website are special products, and market prices have been fluctuating,
The specific customer service quotation shall prevail, as the product is a new one and the traps are not real,
Please confirm the model, product, price, and other detailed information with customer service before placing an order. The website has been used,
The new one is for sale, please contact customer service to communicate.
Model recommendation:
IS420UCSCH1B
IS420ESWBH3A
IS420UCSBH1A
IS420ESWBH3A-C
IS420YAICS1B
IS420UCSBS1A
IS420ESWBESWB
IS420UCSCH2A-E-V0.1-A
IS420UCSBH3A-UCSB
IS420UCSBS1A-UCSB
vibro-meter 204-656-000-1301
CB06560 PRD-B040SAIB-62
UVC656 13-01
CB06560 PRD-B040SAIB-62
Reviews
There are no reviews yet.