Description
IS220PPRFH1A 336A4940CSP20- PROFIBUS Master Gateway Pack is available in stock which ships the same day.
IS220PPRFH1A 336A4940CSP20- PROFIBUS Master Gateway Pack comes in UNUSED as well as REBUILT condition.
To avail our best deals for IS220PPRFH1A 336A4940CSP20 – PROFIBUS Master Gateway Pack, contact us and we will get back to you within 24 hours.
Mark VI General Electric module IS220PPRFH1A 336A4940CSP20 is labeled a Profibus Master Gateway Analog I/O Pack and works with the IS200PIDG1A accessory board. This model was rated to operate in hazardous and non-hazardous locations.
IS220PPRFH1A 336A4940CSP20 Other names:
Input/output modules IS220PPRFH1A 336A4940CSP20
IS220PPRFH1A 336A4940CSP20 analog module
Information modules IS220PPRFH1A 336A4940CSP20
Product Description
Model number IS220PPRFH1A 336A4940CSP20 is described within the Mark VI series produced by General Electric as a PROFIBUS Master Gateway Module. While this model was designed to be used in the Mark VI series, it can also be used in the Mark VIe and Mark VIeS series. The PPRF model is considered an analog output pack and is often used with the IS220PPRFH1A 336A4940CSP20 accessory ID board. Together the I/O pack and the terminal board were rated and approved for hazardous and non-hazardous locations.
When the IS220PPRFH1A 336A4940CSP20 model is being used, there are electrical specifications that must be followed so as to eliminate potential property damage or some cases, personal injury. There are two specifications, labeled voltage and current. The power supply voltage has a range of 27.4 to 28.6 VDC, with the nominal voltage supply being 28.0 VDC. The power supply current used by the PPRF pack is a maximum of 0.18 ADC. There is also a specific temperature range the PPRF model must be used in; this temperature range is -4 to 131°F or -20 to 55°C.
As mentioned above, the IS220PPRFH1A model was rated for use in hazardous and non-hazardous locations. For each location, there is a listing certification. The non-hazardous certification is UL E207685, which is the same as the Class I, Division 2, Groups A, B, C, D, and Class I, Zone 2, Group IIC certifications. The certification for ATEX Zone 2, Group IIC is UL DEMKO 12 ATEX 1114875X. For more certifications, refer to the GEH-6725 Mark VIe and Mark VIeS Controls Equipment HazLoc manual.
IS220PPRFH1A 336A4940CSP20 is a PROFIBUS Master Gateway pack developed by GE. The PROFIBUS Master Gateway (PPRF) pack is a PROFIBUS DPV0, Class 1 master that maps I/O from PROFIBUS slave devices to I/O Ethernet Mark VIe controllers. The module includes a processor board shared by all Mark VIe distributed I/O modules and an acquisition carrier board outfitted with a Hilscher GmbH COM-C PROFIBUS communication module.
IS220PPRFH1A 336A4940CSP20 Functional Description
A PROFIBUS RS-485 interface is provided by the COM-C module via a DE-9 D-sub receptacle connector. It functions as a PROFIBUS DP master, with transmission rates ranging from 9.6 KBaud to 12 MBaud and up to 125 slaves, each with 244 bytes of inputs and outputs.
Other IO packs use the same dual I/O Ethernet connection configuration. In the hot-backup mode, however, two PPRFs are used, one as the active PROFIBUS master communicating with slave devices and the other in a passive, stand-by mode, ready to become the active master in the event of an active master failure.
Features
The following redundancy options are supported by the PPRF:
One I/O pack with one Ethernet connection (no redundancy)
Dual I/O Ethernet connections on a single I/O pack
Dual I/O Ethernet connections on the hot-backup I/O pack
Compatibility
The PROFIBUS Master Gateway Terminal board (SPIDG1A) is used to install the PPRF and provide an electronic ID. Its only connection is to the PPRF, as the PROFIBUS connection is made to the DE-9 D-sub receptacle connector exposed on the PPRF’s side. On the PPRF, indicator LEDs provide visual diagnostics.
The number of I/O packs used in a signal path is referred to as the control mode:
Simplex employs a single I/O pack and one or two network connections.
Hot backup employs two I/O packs, each with two network connections.
IS220PPRFH1A Installation
Firmly secure the SPID terminal board.
Insert the PPRF directly into the terminal board connector. Repeat steps 1 and 2 with a second SPID and PPRF for hot-backup configurations.
Use the threaded inserts next to the Ethernet ports to mechanically secure the packs. The inserts connect to a terminal board-specific mounting bracket. Adjust the bracket so that no right angle force is applied to the DC-37 pin connector between the pack and the terminal board. This adjustment is required only once during the product’s lifetime.
Depending on the system configuration, connect one or two Ethernet cables. The pack can be used with either port. Standard practice is to connect ENET1 to the network associated with the R controller when using dual connections; however, the PPRF is not sensitive to Ethernet connections and will negotiate proper operation over either port.
Insert the PROFIBUS cable into the DE-9 D-sub receptacle connector and secure it. PROFIBUS must be terminated on either end, according to PROFIBUS specifications.
Connect power to the connector on the pack’s side. It is not necessary to insert the connector with the cable’s power disconnected. The PPRF includes an inherent soft-start capability that regulates current inrush during power application.
Configure the I/O pack and PROFIBUS as needed using the ToolboxST application.
Frequently Asked Questions
What is IS220PPRFH1A 336A4940CSP20?
IS220PPRFH1A 336A4940CSP20 is a PROFIBUS Master Gateway developed by GE
What type of I/O pack is the IS220PPRFH1A 336A4940CSP20 model?
The IS220PPRFH1A 336A4940CSP20 pack is labeled by General Electric as an analog I/O pack. This model is specifically labeled a PROFIBUS Master Gateway Module.
Does the IS220PPRFH1A 336A4940CSP20 model interface with any terminal boards with the Mark VI, VIe, or VIeS series?
There is one specific terminal board that the IS220PPRFH1A model will interface with; this model is labeled as the IS220PPRFH1A 336A4940CSP20 accessory ID board.
Are the only certifications for the IS220PPRFH1A 336A4940CSP20 model listed in the description?
No, there are several more locations/certifications that the IS220PPRFH1A 336A4940CSP20 model can be used. Another one of the standards of the IS220PPRFH1A model is ANSI/ISA-12.12.01-2015 or CAN/CSA-C.22.2 No. 213-15. These standards are classified under Class I, Division 2, Groups A, B, C, and D.
Where can I find information regarding the PPRF model?
Information on the PPRF model would be found in any available Mark VI, Mark VIe, or Mark VIeS documentation. One of the primary sources of information is the GEH-6725 Mark VIe and Mark VIeS Controls Equipment HazLoc Guide, which only provides information regarding standards and certifications and the electrical ratings of the model.
Reviews For IS220PPRFH1A 336A4940CSP20
The IS220PPRFH1A 336A4940CSP20 model has ventilation slots that must remain uncovered at all times. If the ventilation slots are covered at any time, it could cause a build-up of dust and inhibit the airflow needed. If there is a dust build-up, it could affect the functionality of the unit.
All products on this website are special products, and market prices have been fluctuating,
The specific customer service quotation shall prevail, as the product is a new one and the traps are not real,
Please confirm the model, product, price, and other detailed information with customer service before placing an order. The website has been used,
New for sale, please contact the website https://www.weikunfadacai1.com/ Customer service communication.
Popular models:
IS220YDIAS1A
IS220PTURH1A
IS220PTCCH1A
IS220YAICS1AJA0C2S7
IS220YDIAS1AJA4F19
IS220YDOAS1AJA1C10P
IS220PAICH1A 336A4940CSP
IS220PAICH2A 336A4940CSP11
IS220PAOCH1A 363A4940CSP5
IS220PDIAH1A 336A4940CSP1
IS200VCRCH1B
angel –
GE IS220PPRFH1A | I/O package | PPRFH1A | Mark VI turbine control system. The Mark VI General Electrical Module IS220PPRFH1A is marked as a Profibus main gateway analog I/O package and can be used with the IS200PIDG1A accessory board. This model has been rated to operate in both hazardous and non hazardous locations. The model IS220PPRFH1A is described as a PROFIBUS main gateway module in the Mark VI series produced by General Electric. Although this model is designed for the Mark VI series, it can also be used for the Mark VIe and Mark VIeS series. The PPRF model is considered an analog output package and is typically used in conjunction with the is200 spidg1a attachment identification board. When using the IS220PPRFH1A model, electrical specifications must be followed to eliminate potential property damage or personal injury in certain situations, as I/O packages and wiring boards are rated and approved for hazardous and non hazardous locations. There are two specifications marked as voltage and current. The range of power supply voltage is 27.4 to 28.6 volts DC. The nominal power supply voltage is 28.0 VDCPPRF. The maximum power supply current used in the group is 0.18. The analog-to-digital converter PPRF model must also be used within a specific temperature range; The temperature range is -4. to 131 ° F or -20 to 55 ° C