Description
369-HI-R-M-0-0-0 Technical Specifications # of Recordable Eventslast 512 events Communicationsnon-isolated RS232 port, RS485 port Differential Switch Time Delay<200 ms Maximum Altitude2000 m (max) Operating Range-40°F (-40°C) to +140°F (+60°C) Phase Current Inputs1 A and 5 A secondary Storage Range-40°F (-40°C) to 176°F (+80°C)
Product Description
The use of appropriate Safety shoes (Omega) safety gloves, safety glasses and protective clothing are recommended during equipment installation, maintenance and service of the equipment. • Failure to observe and follow the instructions provided in the equipment manual(s) could cause irreversible damage to the equipment and could lead to property damage, personal injury and/or death. • Before attempting to use the equipment, it is important that all danger and caution indicators are reviewed. • If the equipment is used in a manner not specified by the manufacturer or functions abnormally, proceed with caution. Otherwise, the protection provided by the equipment may be impaired and can result in impaired operation and injury. • Caution: Hazardous voltages can cause shock, burns or death. • Installation/service personnel must be familiar with general device test practices, electrical awareness and safety precautions must be followed. • Before performing visual inspections, tests, or periodic maintenance on this device or associated circuits, isolate or disconnect all hazardous live circuits and sources of electric power.
Protective system features of the 369-HI-R-M-0-0-0 like Short Circuit Trip are able to limit damage to motor components by detecting excess magnitude and generating an appropriate response. If the magnitude rises above the Phase CT Primary x Pickup Level for a specified amount of time, a trip will transpire. The amount of time can be adjusted in 10 ms increments and configured through the relay’s setpoint system. While accidental tripping can occur during motor start if the short circuit time delay is too sensitive, users can fine tune these settings using system-generated data to find a suitable compromise.
The 369-HI-R-M-0-0-0 has a height of approximately 11.5 inches, a width of 8.5 inches, and a depth of 5.5 inches. The installation cut-out for the relay can be slightly smaller (11”H, 7”W) since the relay diminishes in size towards the back, with the front panel being the largest section of the device. An enhanced faceplate option is also available and will be denoted by an “E” ending the model number on AX Control’s 369 series page.
Frequently Asked Questions about 369-HI-R-M-0-0-0
What does the R option afford the 369-HI-R-M-0-0-0 Multilin GE motor management relay?
The R option of the 369-HI-R-M-0-0-0 indicates that the 369 motor management relay has additional RTD inputs built in to the base unit. These additional 12 RTDs are type 3 wire with either 100 Ohm platinum, 100 Ohm nickel, 120 Ohm nickel, or 10 Ohm of copper composition. The RTD sensing current for the 369 R option is 3 mA. These RTD options range from either negative 40 degrees Celsius to 200 degrees Celsius or from negative 40 degrees C to positive 392 degrees C. The RTD inputs (option R) have an isolation that is 36 Vpk.
Is ventilation required for the GE Multilin digital relay 369-HI-R-M-0-0-0 to function for the protection and monitoring of three phase motors?
The 369-HI-R-M-0-0-0 is a relay within the 369 motor management relay Multilin GE series. This relay is designed to provide protection and monitoring of three phase motors as a motor management digital relay. There are no specific ventilation requirements listed by the manual with the direction to keep the ambient temperature within the specifications listed. In this case for a base unit the ambient temperature range is from -40 degrees C to positive 60 degrees C. Ventilation may be necessary for conditions within sunlight.