ABB PU517 RTA Board 3BSC980050R46

Sale!

ABB PU517 RTA Board 3BSC980050R46

(1 customer review)

¥4,151.00

Description

Many products are not yet on the shelves please contact us for more products

  .If there is any inconsistency between the product model and the picture on display, the model shall prevail. Contact us for the specific product picture, and we will arrange to take photos in the warehouse for confirmation

  .We have 16 shared warehouses around the world, so please understand that it can sometimes take several hours to accurately return to you. Of course, we will respond to your concerns as soon as possible

ABB PU517 RTA Board 3BSC980050R46.it uses to communicate with ABB AC450 Controller.The PU517 real time accelerator is the communication card inside a Unix workstation serving as the op station on Advant.It communicates to the MB300 propriority ethernet bus to the controller subsystems.If this card is missing or faulty, the OS500 application on the Unix will not come up.

CI534V02 3BSE010700R1
 

Key Components

CPU: The CPU module varies based on memory and whether redundancy is supported. Each CPU has two Ethernet ports for connection to workstations, engineering stations, management stations, or advanced applications. These Ethernet ports can be set as redundant to improve system availability. The controller is also equipped with two RS232 ports for debugging tools or communication

Communication Modules: Next to the CPU module, a series of communication modules or I/O modules can be added. For example, additional RS-232C interfaces can connect more external systems or devices. Profibus DP, DP/V1 interfaces allow S800, S900 I/O systems to be integrated in a remote I/O way and support Profibus-compliant products and devices on the market. Masterbus 300 interface supports Advant OCS and ABB Master systems. Various other interfaces and I/O modules

Industrial control data acquisition card is a computer based on embedded microprocessor, which can collect and process various industrial control signals in real time, and convert them into standard data signals that can run in various standard industrial control environments (such as: CNC machine tools, hydraulic, electric power, aerospace, etc.). In some industrial control sites, there will be a large number of data acquisition signals, such as: relay contact signals generated when PLC code is executed, and relay contact signals generated when PLC program is executed. A special digital communication interface data communication card designed and developed to meet the needs of a large number of signals and information processing in the field. It is composed of hardware devices and operating systems, which can be used independently or work together with other digital communication devices to form a network. This series of acquisition card is designed based on embedded microprocessor chip, with high-performance DSP as the core processing system, with rich functions and characteristics, supporting 8-bit and 16-bit analog input/output, and using high-quality industrial audio chip for audio signal processing; Transparent PC board structure design; It can be used with the acquisition card through SPI interface. This series of acquisition card has 4 series (PCI+RS-485), 4 interface modes (PCI mode, RS-485 mode, Modbus+RS-485 mode) optional.(https://www.weikunfadacai1.com/)

Power protection relays and automation products: Relion, substation automation, distribution protection and control, transmission protection and control.

Power Electronics: SYNCHROTACT Concurrent Devices, High Power Rectifiers, Control Systems.

CI534V02 3BSE010700R1(1)
 

Control Systems: 800xA, Advant open control system with Master software, Advant open control system with MOD 300 software, Freelance, Melody series, SATT, Symphony DCI series, Symphony Harmony INFI 90 series, Compact 800.

Process Automation: ABB Process Automation provides customers with instrumentation, automation products and industrial process optimization solutions for the oil, gas, power, chemical, pharmaceutical, pulp, paper, metals, minerals, marine and turbocharging industries.

CI534V02 3BSE010700R1(2)
 

The major features of the AC 800M are:

• High performance and large application memory.

• Extensive availability.

• CPU redundancy

(PM858/PM861/PM862/PM864/PM865/PM866/PM867/PM891).

• AC 800M High Safety Integrity Level 2 certified using PM865/SM810/SM811

or PM867/SM812.

• AC 800M High Safety Integrity Level 3 certified using PM865/SM811 or

PM867/SM812.

• Built-in redundant Ethernet channels.

• Built-in RS-232C channels.

• Sectioned CEX-Bus using a pair of BC810 / BC820.

• Quick and simple fault-finding with the aid of LEDs on each unit / channel.

• Built-in battery back-up of memory (except for PM891).

• External battery back-up.

• Use of industry standard power supply voltage – 24V d.c.

• Easy mounting on standard DIN rail.

• IP20 Class protection without the requirement for enclosures.

• Incorporation of a wide variety of communication possibilities.

• Hardware based on standards for optimum communication connectivity

(Ethernet, PROFIBUS DP).

• Support for PROFIBUS DP fieldbus.

• Support for FOUNDATION Fieldbus.

• Support for Advant Fieldbus 100.

• Support for Modbus TCP

Some of the benefits of the AC 800M Controller are:

• Flexibility, the AC 800M Controller can be ordered as individual units which

may be mounted in accordance with the customers own requirements.

• Extremely small footprint.

• Simple DIN rail attachment / detachment procedures, using the unique slide

& lock mechanism.

• Modularity, allowing for step-by-step expansion. You only pay for what you

require at the present time.

• Reliability and simple fault diagnosis procedures.

• Controller redundancy for higher availability (CPU, CEX-Bus, communication

interfaces, S800 I/O).

• Built-in redundant Ethernet Communication ports.

• Built-in RS-232C communication ports.

• Low power consumption, thus no external fans required.

• Flexible process connection, using either local I/O or standard fieldbuses.

• S800 I/O redundancy.

• Supports S800 I/O High Integrity (with PM858, PM862, PM865, PM866A,

PM867 and PM891).

  Parts you may need for your project:

PU512V1 3BSE004736R1 PU512V1 Real Time Accelerator (RTA) Module

PU512V2 3BUR001401R1 PU512V2 Real Time Accelerator (RTA) Module

PU514A 3BSE032400R1 PU514A Real-Time Accelerator (RTA) board for PCI

PU515 3BSE013063R1 PU515 Real Time Accelerator Module – PCI

PU515A 3BSE032401R1 PU515A Real-Time Accelerator (RTA) board for PCI

PU518 3BSE018680R1 Real Time Accelerator (RTA) Board

PU519 3BSE018681R1 PU519 Real Time Accelerator (RTA) Board

NKTU11-20 I/O Module to Termination Unit Cable

NKTU11-24 I/O Module to Termination Unit Cable

NLIM02 Loop Interface Module

NLIM03 LOOP INTERFACE

NLIS01 Loop Interface Slave

NLMM01 LOOP INTERFACE

NLMM02 LOGIC MASTER

NLSM01 Network 90 Loop Storage

NLSM02 Loop Storage Module

NMFC01 LOOP STORAGE

NMFC02 Multi-Function Controller

NMFC03 Enhanced Multi-Function Controller

NMFC04 Multifunction Controller – NET 90

NMFC05 Multifunction Control Module

NMPC01 PC90 Processor Module

NMFP01 MULTI FUNCTION CONTROL

NMFP02 TUNING TERMINAL PCB

NMFP03 PROCESSOR BOARD

NMMU01 PROCESSOR BOARD

NMMU02 I/O RACK

NMPC01 I/O RACK

NMPP02 POWER PANEL

NMPP02-W PROCESSOR MOD

NMPP02-W/O MOD POWER SUPPLY

NMRT01 MANUAL MODULE

NETWORK INTERFACE

NPBS01 PARALLEL BUS

NPCS01 PULVERIZER CONTROL

NPCS02 PULVERIZER CONTROL

NPEP01 POWER ENTRY PANEL

NPEP02 Network 90 Power Entry Panel

NPEP03 POWER ENTRY PANEL

NPIM01 Processor Interface Module

NPRT02 PRINTER

NPSI02 Module Power Supply

NPSI03 I/O POWER SUPPLY

NPSI04 I/O POWER SUPPLY

NPSM01 Power Supply

NPSM02 Power Supply

NPSM03 MOD POWER SUPPLY

NPSM04 MOD POWER SUPPLY

NPTM01 Point Table Module

NQRC01 QUICK RESPONSE MODULE

NQRS02 QUICK RESPONSE MODULE

NRI002 PCB Remote I/O

NRLO02 MODULE

NSBM01 Superloop Bus Module

NSCM01 SERIAL COMMUNICATION MODULE

NSCT01 TOUCH SCREEN

NSIM01 SERIAL INTERFACE MODULE

NSMS01 POWER SUPPLY

NSPM01 Serial Port Module

NSPS01 POWER SUPPLY

NSPS02 POWER SUPPLY

NSSM01 SUPER LOOP STRG

NTAI01 Analog Input Termination Unit

NTAI02 Analog Input Termination Unit

NTAI03 Analog Input Termination Unit

NTAI04 TERMINATION BD

NTAI05 Analog Input Termination Unit

NTAI06 Analog Input Termination Unit

NTAM01 Analog Master Termination Unit

NTAO01 Analog Output Termination Unit

NTCF02 Termination Unit – Optic to Electronic

NTCF03 Termination Unit – Electric to Optical

NTCF21 Infinet Fiber Optic Termination Unit

NTCF22 Fiber Optic Communication Termination Unit

NTCF23 Fiber Optic Communication Termination Unit

NTCL01 Communication Link Termination Unit

NTCS02 Control I/O Termination Unit

NTCS04 Control I/O Termination Unit

NTCU01 TERMINATION BD

NTDI01 Digital I/O Termination Unit

NTDI02 Digital I/O Termination Unit

NTDO01 Digital Output Termination Unit

NTDO02 Digtal Output Termination Unit

NTFB01 Fieldbus Module Termination Unit

NTLS01 Logic Station Termination Unit

NTMF01 Multi-Function Controller Termination Unit

NTMP01 Multi-Function Processor Termination Unit

NTMU01 Termination Mounting Unit

NTMU02 Termination Unit Mounting Unit

NTPL01 Plant Loop Termination Unit

NTRL01 Remote Link Termination

  NTRL02A Fiber Optic Remote I/O Termination Unit

NTRL02B Fiber Option Remote I/O Termination Unit

NTRL03 Remote Link Termination Unit

  NTRL03-TU TERMINATION BD

NTRL03-TV TERMINATION BD

NTTA01 TERMINATION BD

NTSM01 Server Module Termination Unit

NTST01 Time Synch Termination Unit

NTU-716 Digital Input Termination

NTU-7C6/MO Termination Unit

NTU-7Q2E Relay Termination Unit

OP27-Display-Color Replacement LCD Screen for OP27 Color

  PAA 02 PAA02 Analog Output Module

PAB 02 369059A10 PAB02 Binary Output Module

1 review for ABB PU517 RTA Board 3BSC980050R46

  1. admin

    admin

    ABB PU517 RTA Board 3BSC980050R46.it uses to communicate with ABB AC450 Controller.The PU517 real time accelerator is the communication card inside a Unix workstation serving as the op station on Advant.It communicates to the MB300 propriority ethernet bus to the controller subsystems.If this card is missing or faulty, the OS500 application on the Unix will not come up.

Add a review

Your email address will not be published. Required fields are marked *