EATON XVS-460-57MPI-1-1E

Sale!

EATON XVS-460-57MPI-1-1E

¥3,514.00

Description

 

EATON
 XVS-430-10MPI or  XVS-430-12MPI or  XVS-440-10MPI or  XVS-440-12MPI or  MS2-430-10MPI or  MS2-430-12MPI or  MS2-440-10MPI or  MS2-440-12MPI Requirements for the place of installation  Approvals: The device must only be used in locations that are approved for the device. See the markings on the nameplate and Chapter 9 Technical data,  55.  Power supply: The power supply must comply with the requirements stated in Chapter 9.5.1 Power supply,  60. 5.2.1 Engineering conditions of acceptability by Underwriters Labaratories Inc. (UL) The device must be installed in an end-product. For the approval in accordance with the standard UL 60950, consideration must be given to the following:  The environment of the device must comply with pollution degree 2.  The device must be supplied via a SELV source.  The device must be connected to the protective earth of the end-product (the functional earthing connection of the power supply interface must be connected).  In order to protect the device from potential internet threats,

EATON(2)
it should be connected to Ethernet networks that are isolated from the internet or safety protected and isolated from the Corporate/Enterprise network by a firewall or router.  Fire protection and electrical protection must be ensured via the end-product (not required for the front of the device). 5.2.2 Requirements for the mounting position The device is designed for mounting in control cabinets, control panels or control desks. 10.4″ and 12.1″ devices can be mounted horizontally or vertically, 15″ devices must only be mounted horizontally. The following requirements must be fulfilled when selecting a suitable mounting position:  The device should not be exposed to direct sunlight (Sunlight disturbs the infra-red touch sensor. In addition, when exposed to UV light, plastic parts of the device can embrittle and the lifespan of the device is reduced).  If the device is to be used in potentially explosive atmospheres, the device must not be subjected to hazardous knocks.  The operating elements on the service side of the device and the cable connections are accessible after the device has been mounted.  The ambient conditions stated must be observed. See Chapter 9.9 Ambient conditions,  62.  Sufficient ventilation (cooling) must be ensured by means of:

EATON(1)
 Clearance of at least 3 cm to the ventilation slots  Clearance of at least 15 cm from heat radiating components such as heavily loaded transformers  The expected temperatures should be within the permissible range. See Chapter 9.9 Ambient conditions,  62.  Properties of the mounting surfaces:  Material thickness at the mounting cutout 2…5 mm  Flatness  0.5 mm (this requirement must also be fulfilled when the device is mounted!)  Surface roughness Rz  1201 Strip the cable end so that approx. 3 cm of the shield braid is exposed. 2 Fold back the shield braid over the cable shield. 3 Fit approx. 3 cm of heat shrinkable tubing over the folded back end of the shield braid or use a rubber grommet.  5…8 mm of the shield braid must be exposed at the cable end.  The folded back shield braid end must be covered by the heat shrinkable tubing or by the rubber grommet. 4 Fit the D-Sub connector to the cable end:  The exposed metal shield braid must be clamped to the connector casing with the cable clamp.Additional product information (links) IL04802011Z Enclosed kit information IL04802011Z Enclosed kit information ftp://ftp.moeller.net/DOCUMENTATION/AWA_INSTRUCTIONS/IL04802011Z2018_02.pdf MN04802011Z Operator manual XVS400 5.7″/8.4″ MN04802011Z Bedienerhandbuch XVS400 5,7″/8,4″ – Deutsch ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN04802011Z_DE.pdf MN04802011Z Operator manual XVS400 5.7″/8.4″ – English ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN04802011Z_EN.pdf MN04802093Z XSoft-CoDeSys-2, PLC programming XVS400 MN04802093Z XSoft-CoDeSys-2, SPSProgrammierung XVS400 – Deutsch ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN04802094Z-DE.pdf MN04802093Z XSoft-CoDeSys-2, SPSProgrammierung XVS400 – Deutsch ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN04802094Z_DE.pdf MN04802093Z XSoft-CoDeSys-2, PLC programming XVS400 – English ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN04802094Z-EN.pdf MN04802093Z XSoft-CoDeSys-2, PLC programming XVS400 – English ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN04802094Z_EN.pdf MN048008ZU Manual XSOFT-CODESYS-3, PLC programming MN048008ZU Handbuch XSOFT-CODESYS-3, SPS-Programmierung – Deutsch ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN048008ZU_DE.pdf MN048008ZU Manual XSOFT-CODESYS-3, PLC programming – English ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN048008ZU_EN.pdf

Reviews

There are no reviews yet.

Be the first to review “EATON XVS-460-57MPI-1-1E”

Your email address will not be published. Required fields are marked *