Description
DS200TBQCG1ABB – RST ANALOG TERMINATION BOARD is available in stock which ships the same day.
DS200TBQCG1ABB – RST ANALOG TERMINATION BOARD comes in UNUSED as well as REBUILT condition.
To avail our best deals for DS200TBQCG1ABB – RST ANALOG TERMINATION BOARD, contact us and we will get back to you within 24 hours.
DS200TBQCG1ABB Other names:
PCB module DS200TBQCG1ABB
DS200TBQCG1ABB Controller Module
Main control board DS200TBQCG1ABB
Regarding DS200TBQCG1ABB
This DS200TBQCG1ABB General Electric printed circuit board product was originally launched as a member of the Mark V turbine control system series. As the name suggests, this product has specific applications in the control and management systems of wind, natural gas, and steam turbine components. The Mark V series to which this DS200TBQCG1ABB PCB belongs can also be defined as General Electric’s traditional series, as its original retailer has ceased production of the series since its inception. Although the Mark V turbine control system series is a traditional series, it is one of the recently developed General Electric product lines that incorporates its iconic patented Speedtronic technology in its assembly. This DS200TBQCG1ABB printed circuit board, or PCB for short, is more suitable for defining as an analog input milliampere I/O terminal module. This is the official functional product description in the original Mark V series instruction manual material. Although the DS200TBQCG1ABB PCB itself is an analog milliampere I/O terminal module, it is not the original product with the expected functionality in the Mark V; That is to say, the DS200TBQCG1ABB analog milliampere I/O terminal module is missing three key product revisions for this DS200TBQCG1ABB board.
Hardware tips and specifications
Like any Mark V series product with a normal Mark V assembly style, this DS200TBQCG1ABB printed circuit board requires specific series of hardware components and component specifications to achieve its expected series functionality. The GE RST analog terminal board DS200TBQCG1ABB has 2 terminal blocks, each containing 83 signal line terminals. The GE RST analog terminal board DS200TBQCG1ABB also includes 15 jumpers, 3 40 pin connectors, and 3 34 pin connectors. Fortunately, for our purposes, the exact application of these different connectors is detailed in the original Mark V series instruction manual material. Some of the different types of connectors include:
JBR TCQA board input/output signal connector
JFR TCQA board LVDT/R position input signal connector
JBS/T connector
JFS/T connector
Test connector
All connectors listed in this DS200TBQCG1ABB analog input milliampere I/O terminal module component are named based on their original factory printed indicator labels, compatibility with other Mark V series printed circuit boards, and specific combinations used for the DS200TBQCG1ABB board and Mark V series automatic drive components, except for JBS/T, JFS/T, and TEST connectors. These three related connectors in the DS200TBQCG1ABB module component are usually not used during normal operation, so they do not have functional names. The various configurations of manually movable hardware jumpers provided by this DS200TBQCG1ABB product can be found in the original instruction manual of this DS200TBQCG1ABB PCB attached in the manual tab.
The DS200TBQCG1ABB circuit board is 11.25 inches long and 3 inches high, designed specifically for installation in rack cabinets, with a hole at each corner for connecting the circuit board. The installation holes drilled by the factory on each corner have undergone insulation treatment to avoid static electricity damage to the DS200TBQCG1ABB base circuit board. When installing the DS200TBQCG1ABB circuit board, it will align with the corresponding holes on the rack, and you can use the screws obtained after removing the defective circuit board to connect the circuit board. Only qualified maintenance personnel can replace the DS200TBQCG1ABB circuit board, as the high voltage present in the driver is very dangerous. Even if the driver is powered off, capacitors and other components will still store voltage. If voltage still exists in the driver, it may cause serious injury when attempting installation. The capacitors of DS200TBQCG1ABB PCB will lose their stored voltage after 30 seconds, so the best practice is to wait for 30 seconds after power failure before touching any components. Before making the final purchase decision for this DS200TBQCG1ABB analog input milliampere I/O terminal module, it is important to realize that this General Electric printed circuit board or module component has been modified three times from its original performance specifications and dimensions.
Frequently Asked Questions about DS200TBQCG1ABB
What is the connector on DS200TBQCG1ABB?
DS200TBQCG1ABB has JBR, JFR, JBS/T, JFS/T, and TEST connections. The last three connections on DS200TBQCG1ABB are usually not used. The connector JBR on DS200TBQCG1ABB writes the 4-20 mA input signal to the TCQA board and reads the milliampere output signal from the corresponding core wire. The connector JFR on DS200TBQCG1ABB writes the LVDT/R position input signal to TCQA.
What is the jumper wire connecting to DS200TBQCG1ABB?
DS200TBQCG1ABB has jumper wires BJ1-BJ17. The jumpers BJ1 to BJ15 on the DS200TBQCG1ABB connect the milliampere input signals 1-15 on the DS200TBQCG1ABB to the DCOM. The jumpers BJ16 and BJ17 on DS200TBQCG1ABB select the maximum current output range for milliampere output. The maximum current for the two milliampere output signals on DS200TBQCG1ABB is either 20 mA or 200 mA.
Where is DS200TBQCG1ABB located?
The DS200TBQCG1ABB is located in the Mark V LM control panel. DS200TBQCG1ABB is located on the,, andcores.
All products on this website are special products, and market prices have been fluctuating,
Please refer to the customer service quotation for details, as the product is new and the price is not genuine,
Please confirm the model, product, price, and other detailed information with customer service before placing an order. The website has been used,
The new one is for sale, please contact customer service for further communication.
Model recommendation:
DS200TCQCG1BBA
DS200TCQBG1B
DS200TBQCG1AAA
DS200TCQBG1BCA
DS200TCCBG3BED
DS200TCQAG1BHF-W01
DS200TCQAG1BHF-W01
DS200TCDAH1BHE
DS200TCQBG1BCB
DS200TCPSG1AEE
DS200FSAAG1ABA
DS200SHVMG1AFE
DS200LDCCH1AKA
DS200SI0CG1A6A
DS200SHVMG1AGE
DS200SI0CG1AEA
DS200PCCAG1ACB
DS200UCPBG6AFB
DS200TCQCG1BJF
DS200DCFBG1BLC
more…
admin –
This DS200TBQCG1ABB General Electric printed circuit board product was originally launched as a member of the Mark V turbine control system series. As the name suggests, this product has specific applications in the control and management systems of wind, natural gas, and steam turbine components. The Mark V series to which this DS200TBQCG1ABB PCB belongs can also be defined as General Electric’s traditional series, as its original retailer has ceased production of the series since its inception. Although the Mark V turbine control system series is a traditional series, it is one of the recently developed General Electric product lines that incorporates its iconic patented Speedtronic technology in its assembly. This DS200TBQCG1ABB printed circuit board, or PCB for short, is more suitable for defining as an analog input milliampere I/O terminal module. This is the official functional product description in the original Mark V series instruction manual material. Although the DS200TBQCG1ABB PCB itself is an analog milliampere I/O terminal module, it is not the original product with the expected functionality in the Mark V; That is to say, the DS200TBQCG1ABB analog milliampere I/O terminal module is missing three key product revisions for this DS200TBQCG1ABB board.