HE693THM884K GE

Sale!

HE693THM884K GE

¥1,111.00

Description

brand; GE
model; HE693THM884K
QQ email; xiongbacarrey@qq.com
weight; 11kg
Specifications; 12cm
Telephone; 86 18030177759
contacts;  Carrey
address; Xiamen Xiongba E-commerce Co., Ltd., Unit 2009, Luling Road, Siming District, Xiamen City, Fujian Province
Personal official website https://www.weikunfadacai1.com
Properties: Purpose Rack Interface, PLC Control, Analog Input, Motor Mechanical Protection, Voltage Sensing, System Control
Specification: medium, 20 * 15 * 16, 20 * 30 * 16, 10 * 16 * 23
Features: high security, high efficiency, high security, high precision, safe, efficient and durable, secure encryption, stable and efficient, stable and energy-saving
System environment: normal temperature, high temperature resistance
Operating system: 3500 security system, ISI system, PLC system

Powerful and programmable system

Applicable industry: power plant steel plant cement plant ship papermaking
Service advantages: after-sales guarantee and sufficient supply
Express: Shunfeng/Deppon Express Land
Sales scope:  worldwide
Output frequency: 50/60
Product certification: original factory certification

Model OK

Working voltage:  24Vdc/120Vac
Color: natural standard color

The GE Fanuc’s IC698RMX016 is a 16MB Redundant Memory Xchange for the Rx7I Pacsystem. It has the following sizing: 6.299 inches widde x 9.187 inches high. It has 16MB of SDRAM user memory. The operating voltage from power supply is +5 V DC. Current requirements are 1.8A. The unit has a fiber optic LC type connector which, conforms to IEC 61754-20, and a zirconium ceramic ferrule. The maximum insertion loss is 0.35 dB with a return loss of -30dB. An acceptable temperature range is between -20°C and +85°C. To complete installation, you need to make sure you have all of the following: A PACSystems RX7i CPU with release 2.00 or later firmware; a PACSystems Rx7i CPU rack with power supply; a PC-compatible computer with CIMPLICITY Machine Edition – Logic Developer PLC, version 4.5 or later programming software and the necessary cables.HE693RTD600
Note that in order to meet radiated emission standards, RX7i systems that include more than one Memory Xchange modules have to be installed in a conducting metal enclosure, or equivalent. Memory modules should only be installed in RX7i Rack 0 (main). It is advised that RMX modules are installed in slots 4 and 3 of the main rack. This provides the RMX modules VME interrupt request priority. Although such configuration is advisable, locating RMX modules in slots 4 and 3 is not strictly required. To install IC698RMX016 Redundant Memory Xchange, make sure the rack power is switched off. Next slide the module into the exact slot it was configured for in the system. Proceed to press the board in place without forcing it. HE693RTD600(1)Tighten faceplate top and bottom screws. Next make sure to connect cables to RX and TX connectors. The fiber optic cable should be routed from the TX connector to next node’s RX connector. Connect the that board’s TX cable to next node’s RX connector. Repeat until last node in the ring has its TX routed to the RX connector of the first node. Turn the power on.The IC698RMX016 initially powers in a non-configured state where its optical transmitter is disabled. The Redundant Memory Xchange module will not operate on a network before the RX7i CPU sends the module a hardware configuration. HE693RTD600(2)For the purpose of reflective memory operation, the user can choose to configure the following parameters: Redundant Transfer Mode, Node ID, Network Memory Offset, Rogue Master, and Interrupt enable. Note that if the Redundant Link operation is selected, the above-mentioned parameters will be set by the CPU and are therefore not configurable. Note that when IC698RMX016 is used as a reflective memory module with a general purpose, additional functions that extend beyond the basic read and write operations, inclusive of reading interrupt status, enabling interrupts, reading parity errors, and enabling parity may be performed by user logic.

[service contact information]
Tel: 18030177759 (WeChat with the same number)
QQ : 2797820256
Email: xiongbacarrey@qq.com
Website: https://www.weikunfadacai1.com
Address:Unit 2009, 20th Floor, 1733 LUling Road, Siming District, Xiamen
Shipment: EMS,DHL,UPS & FEDEX
Payment: T/T
Supply Ability: 30 Unit/Units per Month
Price: The more you order ,the lower price you will get
Delivery: In stock,within 3 days send the products
Address: Unit 2009, Chuangxiang Center, No.1733, Lvling Road, Siming District, Xiamen
①24-hour email reply (12 hours);
③For shipment to countries outside Asia, please contact the seller.
Xiamen Xiongba E-commerce Co., Ltd;

ABB PLC system module system card also includes production stop control system modules and components

General Electric: Fanuc modules, cards, drivers (1C693、IC 694、IC 695、IC 697 1C698、IS 215、)

IS 200, 1C200 series.)

Nevada: 3500/3300 system, front probe, etc.

Schneider Modison: Quantum 140 series processors, control cards, power modules, etc.

Motorola (MVM): MVME 162, MVME 167, MVME 1772, MVME 177 and other series.

Honeywell: (51204166-17551309276-15051400910-100.)

Moore, 6ES5 series, 6GK series, 6DD series, 6AR series.

Inviteys Foxboro: I/A series system, fBM (input/output module) sequential control, ladder logic control, accident recall)

Management, digital analog conversion, input/output signal processing, data communication and processing (FBM 242,P0916 PW,

AD202MU,P0916A.)

Invensys Triconex: Redundant fault-tolerant control system, the most modern fault-tolerant controller based on three module redundant architecture

(3700 A,3008,3503 E.)

Rockwell Allen-Bradley : SLC500/1747/1746 MicroLogix/1761/1763/1762/1766/1764

CompactL Ogix/1769/1768

Logix5000/1756/1789/1794/1760/1788, PLC-5/1771/1785, etc.

Westinghouse: system, WDPF system, WEStation system spare parts.

(1C31223G01,5X00226G01,5X00357G04.)

XYCOM: I/0, VME board and processor.

Yaskawa: servo controller, servo motor, servo driver

Bosch Rexroth: Indramat,/0 modules, PLC controllers, drives, modules, etc.

Woodward: SPC valve position controller, PEAK1 50 digital controller.

Rosemount: pressure transmitter, flowmeter.
SHIPPING
1.For the in stock items, we will ship to you within 3 days after received payment
2.We can shipping all over the world via DHL,UPS,FEDEX,TNT and EMS.
3.If you have shipping agent please tell us before shipment.
4.We will packing the parts with strong box, if you have any special needs, please notify to us.
5.We usually ship up to before 4:30 PM, after shipment we will send the tracking number to you. It will take 7~15 days to receive the packages.
6.When you received the package, please email to us.
7.Please include all information when asking for cost on shipping, or it will slow the process down.
1.What is your zip code?
2.What is your company name if you have one and your name?
3.What is your phone number and extension if you have one?

Reviews

There are no reviews yet.

Be the first to review “HE693THM884K GE”

Your email address will not be published. Required fields are marked *