SR469-P5-HI-A20-T GE

Sale!

SR469-P5-HI-A20-T GE

¥2,781.00

Description

SR469-P5-HI-A20-T technical specifications Maximum power supply 45 VA RTD induced current 5 mA series Chapter 469 Voltage input VT ratio 1.00 to 150.00:1, step size 0.01 CE certified in accordance with EN 55011/CISPR 11 EN 50082-2 CT primary differential phase current 1 to 5000 ampere voltage type high 469 sensor power supply+24 VDC at 20 mA SR469-P5-HI-A20-T has a five ampere phase CT secondary and high rated control power supply (90-300 VDC, 70-265 VAC @ 48-62 Hz.) This specific device has a 4-20 mA analog output. It has a standard front panel.

  Product Description

SR469-P5-HI-A20-T is an SR469 Multilin relay. This is one of several versions of the series that we are preparing to ship in our warehouse inventory. If this specific unit does not meet your exact requirements, please check the other units we sell.

 

SR750-P5-G5-S5-LO-A20-R-T
 

SR469-P5-HI-A20-T has a five ampere phase CT secondary and high rated control power supply (90-300 VDC, 70-265 VAC @ 48-62 Hz.) This specific device has a 4-20 mA analog output. It has a standard front panel. The front panel includes a 40 digit LCD display screen, LED indicator lights, numeric keypad, and other input keys.

The device is equipped with an optional 10BaseT Ethernet port. This can help you connect your device to a 10 Mbps Ethernet network. The 10BaseT port is a supplement to the three standard serial ports built into the SR469 unit. There is an RS232 port on the front panel. This allows for rapid programming and troubleshooting. In addition, there are two RS485 interfaces on the rear panel of the relay. All three serial ports support the ModBus RTU protocol. By adding Ethernet ports, SR469 also supports ModBus RTU through TCP/IP protocol.

The 469 relay is designed to provide voltage and frequency protection, prevent ground faults through two dedicated ground current inputs, detect load loss, reverse active power, current imbalance, and over torque to protect the load from mechanical damage.

 

SR469-P5-HI-A20-H
 

For more information on the SR469-P5-HI-A20-T relay, please refer to the GE Multilin manual. Before unpacking from AX Control, please read through the original GE documentation for information on handling and safety requirements. This is for your safety and to ensure the lifespan of the new equipment.

Frequently asked questions about SR469-P5-HI-A20-T

 

SR469-P5-HI-A20-H(2)
 

How to input motor protection settings for GE’s SR469-P5-HI-A20-T motor relay?

To set motor protection for the SR469-P5-HI-A20-T motor relay, it must be done in the S6 current component settings in the “Motor Protection” title tab. Some settings for this motor protection should remain disabled. Please refer to the manual for more information on the settings that need to remain disabled. Pressing the “MESSAGE” key allows you to move to the next setting message. Since the specifications are not numerical values, these settings must remain “OFF”, and overload alarms, mechanical paper jams, undercurrent, and phase differences must be set to “OFF”. For more specifications on the protection settings of this motor, please refer to the manual with part numbers 1601-0122-A9.

 

 

What additional settings are there when starting the motor of the GE SR469-P5-HI-A20-T motor management relay?

You can find other settings on the S7 motor startup settings page located on the motor protection title page. In the manual, you can find the setting changes for the acceleration timer and start inhibit component. For these elements, the jogging block and restart block need to be set in the “off” position. For the start inhibit component in the S7 motor start setting, the start inhibit block must be “opened” and the TC usage margin must be set to 25%. In the case of an acceleration timer component, the acceleration timer trip must be “locked”, the assigned trip relay must be set to “trip”, and the acceleration timer from start must be set to “13 seconds” and the acceleration curve at 100% voltage. Multilin 469 5 A phase CT secondary with 90-300VDC and 70-265VAC under 48-62Hz control power supply. The Ethernet enhancement module SR469 motor protection system is a member of the SR series of relays, providing protection, control, simplified configuration, and advanced communication in a cost-effective industry leading withdrawable structure. 469 is designed specifically for medium voltage motors, providing advanced protection with customizable overload curves and single CT differential protection to increase flexibility. The 469 also uses the motor setting automatic configurator to provide simplified configuration, allowing for quick and easy setting of motor parameters. Combining advanced protection and diagnostic functions, 469 provides users with the flexibility of multiple communication protocols, allowing integration into new and existing control networks. yes

 

 

Voltage related overload curve, torque measurement and protection, rotor bar break protection, state-of-the-art thermal model – multiple RTD inputs for stator thermal protection to minimize replacement time – complete asset monitoring with drawer structure – temperature, analog I/O, complete measurement to improve the normal operation time of auxiliary equipment – reduced troubleshooting time and maintenance costs through I/O monitoring – event reporting, waveform capture The built-in simulation function of the data recorder simplifies testing and cost-effective information access – through standard RS232 and RS485 serial ports, as well as optional Ethernet and DeviceNet ports, on-site firmware can be upgraded and optional conformal coatings can be set for exposure

Protection and management of three-phase high-power motors and driven equipment, including high inertia, two speed, and step-down starting motors

Thermal model bias start supervision and suppression with RTD and negative sequence current feedback, mechanical paper jamming voltage compensation, acceleration undervoltage, overvoltage underfrequency stator differential protection, thermal overload over temperature protection, phase and ground overcurrent current imbalance, power component torque protection, dual overload curved line step-down start control for 2-speed motors, yes

Yes, 469 is a digital motor protection system designed to protect and manage medium and large motors and drive equipment. It includes a full range of selective activation, independent protection and control components, as detailed in the functional block diagram and menu.

  Popular model recommendations:

 SR469-P5-HI-A20-E  GE

 

Reviews

There are no reviews yet.

Be the first to review “SR469-P5-HI-A20-T GE”