TRICONEX ACM4609

Sale!

TRICONEX ACM4609

¥321.00

Description

Feature flexibility: I/O deployment enables centralized and distributed applications to be modified without stopping operations

Performance: Built in high integrity and fault tolerance capabilities, built-in diagnosis and redundancy management – transparent to users, able to maintain SIL3 high capacity processing even under fault conditions – over 750000 TMR I/O channels with fast scan time (starting from 20 milliseconds) Each controller can store up to 60000 SOEs with advanced input/output monitoring and control capabilities. 1 millisecond SOE timestamp is directly integrated on the I/O module through HART and transmitted to the asset management system. Universal I/O module communication and integration with each point configuration

Up to 254 nodes for point-to-point communication and universal connectivity to all major distributed control systems (DCS), process automation systems, SCADA, and HMI, directly integrated with EcoStruxure Foxboro DCS for maintenance: processors, communication, and I/O modules can be replaced online without stopping operation. Hot spare slots for continuous operation are easy to diagnose, and status and fault analysis can be performed quickly. Online modifications and changes can be made Online module replacement and hot spare slots – software tools that allow continuous production without stopping operations to improve productivity and performance at every step of the safety lifecycle The TriStation software suite uses the TriStation TS1131 system configuration, programming, and documentation to design the system faster. The TriStation emulator can use offline simulation for faster application testing without the need for a physical controller. Enhanced diagnostic monitors can be used to solve maintenance problems faster and retrieve status and health information. The TriStation SOE can be used to retrieve display and analyze process problems, and the Safety Validator can be used to verify/re validate faster New validation application logic, Report generator for automated testing and recording of application logic for custom reports across multiple controllers or projects Use EcoStruxure System Advisor – Process Safety to manage system changes faster Use SIF Manager – Trip Advisor software application to restart operations faster Use Safety View ABM software application to manage priority alerts and bypass applications Security and critical control applications Emergency shutdown (ESD) Fire and Gas (F&G) Burner Management System (BMS) High Integrity Pressure Protection System (HIPPS) Turbomachinery Control and Protection (TMC) Industry: Refining and Petrochemical, Upstream and Midstream Oil and Gas, Chemicals and Specialty Chemicals

 

 

electricity generation; When security and profitability are crucial to your business success, you can rely on the EcoStruxure Triconex security system. Our highly integrated security solution is recognized as the most reliable security system in the market, which can safely drive measurable operational profitability improvement. The EcoStruxure Triconex security system provides lifelong security, providing excellent protection for personnel, production, and profits throughout the entire lifespan of assets. The EcoStruxure Triconex security system is an indispensable component of the EcoStruxure Plant, and Schneider Electric’s open IoT support architecture provides actionable business insights. With over 30 years of continuous secure operation, the EcoStruxure Triconex security system has provided over 1 billion hours of secure runtime. Tricon CX is Triconex’s most powerful security system. Each Tricon CX controller can handle 15 I/O racks, 90 I/O modules, and 2800 physical I/O. Up to 254 nodes can be networked in a single peer-to-peer network, allowing management of over 750000 physical TMR 1/O. Tricon CX provides continuous operation, excellent factory uptime, and high productivity in compact units. Tricon CX provides lifelong flexibility without compromising security. Its simple mechanical design, flexible architecture, and advanced features ensure that your protection can grow with you as your needs change and expand. The design and manufacturing of Tricon CX have excellent usability, allowing for quick and easy design, installation, configuration, operation, and maintenance – reducing overall capital and operational expenses.

 

 

The leading series of high availability and high integrity systems (Tricon, Tricon CX, Trident, and Tri-GP) have been certified by the German Rhine T Å V Safety Integrity Level 3 (SIL3) and can be used for all safety and critical control applications. The EcoStruxure Triconex security system has been proven in the most demanding industries and challenging applications, providing lifetime performance. The Triconex product series includes a comprehensive range of modules. This section includes: system components and their uses, a table listing standard products and their models, and a summary of the specifications for each standard product in the Tricon family. Please refer to the Tricon Planning and Installation Guide for complete information. Tricon Overview Components Housing • Mainframe – Main processor in the house, memory backup battery, communication module, and I/O module Expansion chassis – Additional I/O modules up to 100 feet (30 meters) away from the main chassis. Support for operating up to 1000 feet (300 meters) in restricted applications RXM chassis – used for I/O modules up to 12 kilometers (7.5 miles) away from the main chassis Mechanical keying – Tricon in each slot corresponds to a specific type of module for mechanical keying. This can prevent improper installation of the module into the slot. For chassis installation and housing specifications, see page 25 Power module • Provides logical power to the module, including the main, expansion, or RXM enclosure. Available in 24 VDC, 115 VAC, and 230 VAC versions. The rated power of each power supply is 175 watts at 140 ° F (60 ° C).

 

TRICONEX
 

The main processor executes system diagnostics and user written control programs. Communication Module • Tricon Communication Module (Traditional Chinese Medicine) supports some Triconex protocols and application programs, as well as user written application Ethernet (802.3) networks, including TriStation, Modbus TCP, and OPC. It also supports RS-232 and RS-485 serial communication with Modbus devices, TriStation 1131, and GPS time synchronization Enhanced Intelligent Communication Module (EICM) supports RS-232, RS-422, and RS-485 serial communication Modbus devices and TriStation 1131. • The Network Communication Module (NCM) trumpet supports some Triconex protocols and applications, as well as user written application Ethernet (802.3) networks, including TriStation 1131 The Security Manager Module (SMM) acts as an interface controller between Tricon and the Honeywell Universal Control Network (UCN), one of the three main networks of the TDC-3000 distributed control system The Highway Interface Module (HIM) acts as an interface controller between Tricon and Honeywell TDC-3000 Highway Gateway and Local Control Network (LCN) The Advanced Communication Module (ACM) allows Tricon controllers to interface with Foxboro Industrial Automation (I/A) series DCS and three station 1131. The Fiber Optic Remote Control Expansion Module (RXM) is used to expand the chassis to operate up to 7.5 miles (12 kilometers) of the main box, and has special anti-static and electromagnetic interference capabilities. Interface module • The HART analog input interface module serves as the interface between the 4-20 mA analog input points from the HART smart device on site and the HART host software running on a personal computer The HART analog output interface module serves as the interface between the 4-20 mA analog output point from the HART smart device on site and the HART host software running on a personal computer. The input output module • digital input module receives these nominal discrete signal voltages: 115 VAC/VDC, 48 VAC/VDC, and 24 VAC/VDC. All TMRs provide voltage modules. Non TMR modules are the only ones that provide 24 VDC and 48 VDC. Speed input and accumulation modules are also available Monitor the discrete output signals generated by the digital output module for these nominal voltages, with on-site diagnostic coverage circuits and load devices: 115 VAC, 120 VDC, 48 VDC, and 24 VDC The digital output module produces these discrete output signals with a nominal voltage of 115 VAC, 120

Popular model recommendations:

TRICONEX 3720

 

Reviews

There are no reviews yet.

Be the first to review “TRICONEX ACM4609”

Your email address will not be published. Required fields are marked *