UR9NH GE power module

Sale!

UR9NH GE power module

¥4,142.00

Description

brand; GE
model; UR9NH
QQ email; xiongbacarrey@qq.com
weight; 11kg
Specifications; 12cm
Telephone; 86 18030177759
contacts;  Carrey
address; Xiamen Xiongba E-commerce Co., Ltd., Unit 2009, Luling Road, Siming District, Xiamen City, Fujian Province
Personal official website https://www.weikunfadacai1.com
Properties: Purpose Rack Interface, PLC Control, Analog Input, Motor Mechanical Protection, Voltage Sensing, System Control
Specification: medium, 20 * 15 * 16, 20 * 30 * 16, 10 * 16 * 23
Features: high security, high efficiency, high security, high precision, safe, efficient and durable, secure encryption, stable and efficient, stable and energy-saving
System environment: normal temperature, high temperature resistance
Operating system: 3500 security system, ISI system, PLC system

Powerful and programmable system

Applicable industry: power plant steel plant cement plant ship papermaking
Service advantages: after-sales guarantee and sufficient supply
Express: Shunfeng/Deppon Express Land
Sales scope:  worldwide
Output frequency: 50/60
Product certification: original factory certification

Model OK

Working voltage:  24Vdc/120Vac
Color: natural standard color

IS220PAICH2B Installation
Securely mount the terminal board of choice.
Insert the PAIC I/O pack directly into the terminal board connectors.
Use the threaded studs next to the Ethernet ports to mechanically secure the packs. The studs fit into a terminal board-specific mounting bracket. The bracket should be positioned so that no right-angle force is applied to the DC-37 pin connector between the pack and the terminal board. The adjustment should only be needed once during the product’s lifetime.
Depending on the system configuration, connect one or two Ethernet cables. The pack will work with either port. When using dual connections, it is common practice to connect ENET1 to the network associated with the R controller.URRHH
Connect the pack to power by plugging in the connector on the pack’s side. Because the I/O pack has inherent soft-start capability that controls current inrush on power application, it is not necessary to disconnect power from the cable before plugging it in.
Configure the I/O pack as needed using the ToolboxST application.URRHH(1)
IS220PAICH2B Diagnostics
The I/O pack runs the self-diagnostic tests listed below:

A power-on self-test that includes RAM, flash memory, Ethernet ports, and the majority of the processor board hardware; and
Continuous monitoring of the internal power supplies for proper operation.
A check of the terminal board, acquisition board, and processor board electronic ID information to confirm that the hardware set matches, followed by a check that the application code loaded from flash memory is correct for the hardware set.
Hardware limit checking is performed on each analog input based on preset high and low levels near the end of the operating range. When this limit is reached, a logic signal is generated and the input is no longer scanned. L3DIAG xxxx is a logic signal that refers to the entire board.URRHH(2)
System limit checking is performed on each input based on configurable high and low levels. These limits can be used to generate alarms, enable/disable devices, and as latching/non-latching switches. RESET SYS clears the out of bounds.
Precision reference voltages are included in each scan by the analog input hardware. The measured values are compared to the expected values to confirm the health of the analog to digital converter circuits.
A small burden resistor is used to sense the analog output current on the terminal board. The I/O pack conditions this signal and compares it to the commanded current to ensure the digital to analog converter circuits are in good working order.
The analog output suicide relay is constantly checked for consistency between the commanded state and the feedback indication. The ToolboxST application provides information on individual diagnostics. Individual diagnostic signals can be latched and then reset with the RESET DIA signal if they become healthy.
World of Controls has the most comprehensive selection of GE Speedtronic Mark VIes control replacement components. Our experts are here to help you with your GE needs at any time. If you want any additional information, please contact WOC.
Frequently Asked Questions

Switch Replacement
When the ESWA or ESWB is used to replace an unmanaged switch, the existing mounting brackets, which can be panel or DIN rail mounts, are used. On the present switch, there are seven screw holes for panel mounting.

[service contact information]
Tel: 18030177759 (WeChat with the same number)
QQ : 2797820256
Email: xiongbacarrey@qq.com
Website: https://www.weikunfadacai1.com
Address:Unit 2009, 20th Floor, 1733 LUling Road, Siming District, Xiamen
Shipment: EMS,DHL,UPS & FEDEX
Payment: T/T
Supply Ability: 30 Unit/Units per Month
Price: The more you order ,the lower price you will get
Delivery: In stock,within 3 days send the products
Address: Unit 2009, Chuangxiang Center, No.1733, Lvling Road, Siming District, Xiamen
①24-hour email reply (12 hours);
③For shipment to countries outside Asia, please contact the seller.
Xiamen Xiongba E-commerce Co., Ltd;

ABB PLC system module system card also includes production stop control system modules and components

General Electric: Fanuc modules, cards, drivers (1C693、IC 694、IC 695、IC 697 1C698、IS 215、)

IS 200, 1C200 series.)

Nevada: 3500/3300 system, front probe, etc.

Schneider Modison: Quantum 140 series processors, control cards, power modules, etc.

Motorola (MVM): MVME 162, MVME 167, MVME 1772, MVME 177 and other series.

Honeywell: (51204166-17551309276-15051400910-100.)

Moore, 6ES5 series, 6GK series, 6DD series, 6AR series.

Inviteys Foxboro: I/A series system, fBM (input/output module) sequential control, ladder logic control, accident recall)

Management, digital analog conversion, input/output signal processing, data communication and processing (FBM 242,P0916 PW,

AD202MU,P0916A.)

Invensys Triconex: Redundant fault-tolerant control system, the most modern fault-tolerant controller based on three module redundant architecture

(3700 A,3008,3503 E.)

Rockwell Allen-Bradley : SLC500/1747/1746 MicroLogix/1761/1763/1762/1766/1764

CompactL Ogix/1769/1768

Logix5000/1756/1789/1794/1760/1788, PLC-5/1771/1785, etc.

Westinghouse: system, WDPF system, WEStation system spare parts.

(1C31223G01,5X00226G01,5X00357G04.)

XYCOM: I/0, VME board and processor.

Yaskawa: servo controller, servo motor, servo driver

Bosch Rexroth: Indramat,/0 modules, PLC controllers, drives, modules, etc.

Woodward: SPC valve position controller, PEAK1 50 digital controller.

Rosemount: pressure transmitter, flowmeter.
SHIPPING
1.For the in stock items, we will ship to you within 3 days after received payment
2.We can shipping all over the world via DHL,UPS,FEDEX,TNT and EMS.
3.If you have shipping agent please tell us before shipment.
4.We will packing the parts with strong box, if you have any special needs, please notify to us.
5.We usually ship up to before 4:30 PM, after shipment we will send the tracking number to you. It will take 7~15 days to receive the packages.
6.When you received the package, please email to us.
7.Please include all information when asking for cost on shipping, or it will slow the process down.
1.What is your zip code?
2.What is your company name if you have one and your name?
3.What is your phone number and extension if you have one?

Reviews

There are no reviews yet.

Be the first to review “UR9NH GE power module”

Your email address will not be published. Required fields are marked *