WOODWARD 5464-213 Digital Microprocessor Controller

Sale!

WOODWARD 5464-213 Digital Microprocessor Controller

¥454.00

Description

5464-213 – NetCon SIO Card is available in stock which ships the same day.

  5464-213 – NetCon SIO Card comes in UNUSED as well as REBUILT condition.

  To avail our best deals for 5464-213 – NetCon SIO Card, contact us and we will get back to you within 24 hours.

  Functional Description

5464-213 is a NetCon SIO Card developed by Woodward. The SIO (Serial In/Out) Module connects the VME bus to four serial communication ports. The module is in charge of four serial ports. Ports A (J1) and B (J2) are both RS-232 ports. Ports C (J3) and D (J4) support the RS-232, RS-422, and RS-485 communication protocols. When using 38.4 Kbaud or 57.6 Kbaud, Ports C and D must be at the same baud rate. This module’s processor is a 68030. It manages data transfer between the ports and the VME bus. This module supports up to 4 KB of Dual-Port RAM and 64 KB of PROM. On this module, the local memory supports the 68030 processor. There is only one LED (FAULT) and no switches on the SIO module.(https://www.weikunfadacai1.com/)

5501-471
 

Product Attributes

Ports 1 and 2: RS-232 at 110-38.4 Kbaud

Ports 3 and 4: RS-232, RS-422, and RS-485 (softwareselectable), 110-57.6 Kbaud

Software Support: Modbus RTU, Modbus ASCII, Woodward-specific service interface

Features

The component has four channels

The card also features an interface module that provides additional connectivity options.

NetCon 5000B SIO interface module

Four-port connectivity, which allows multiple devices to be connected to the card simultaneously. This feature is particularly useful for systems that require multiple devices to be connected and communicating with each other in real-time.

To provide visual feedback on the status of the communication channels and other features of the card, the SIO card also includes LED indication.

Weight: 0.73 kgs

Installation

When one or more transmitters are connected to a single receiver using RS-422, termination should be located at the receiver. When a single transmitter is linked to one or more receivers, termination should take place at the receiver furthest away from the transmitter.

Termination for RS-485 should be at both ends of the cable. If termination cannot be placed at the end of a cable, it should be placed as close to the ends as possible. A three-resistor voltage divider between a positive voltage and ground is used to terminate the circuit.

The resistor network’s impedance should be equal to the cable’s characteristic impedance. This is usually between 100 and 120 ohm. The goal is to maintain a voltage level between the two differential lines so that the receiver remains stable. The differential voltage can be between 0.2 and 6 V, with a maximum voltage of less than 10 V between either receiver input and circuit ground. Each port on the SIO board has its own termination resistor network.

The resistor network is connected via the 9-pin connectors on pins 6 and 9.

  Frequently Asked Questions

  What is 5464-213?

  It is NetCon SIO Card developed by Woodward.

  Are there any specific requirements for baud rates on Ports C and D?

  When using the baud rates of 38.4 Kbaud or 57.6 Kbaud, Ports C and D must be set to the same baud rate. This ensures proper communication between the connected devices.

  What processor does the SIO module use?

  It utilizes a 68030 processor. This processor handles the data transfer operations between the serial ports and the VME bus.

  What memory capacity does the module support?

  It supports up to 4 KB of Dual-Port RAM and 64 KB of PROM. The local memory on this module is specifically designed to support the 68030 processor.

  What are the supported software protocols?

  The SIO module supports various software protocols, including Modbus RTU, Modbus ASCII, and Woodward-specific service interface. These protocols enable communication with compatible devices and systems.

Model recommendation:

ABB tension sensor 3BSE004214R1

ABB tension sensor PFTL101BE 2.0KN 3BSE004214R1

ABB Central Processing Unit 3BHE039770R0102

ABB Central Processing Unit PPD539A102 A 800PEC 3BHE039770R0102

ABB high-voltage frequency converter spare parts ACS6000 S-123H

ABB high-voltage frequency converter spare parts ACS6000 S-123H 3BHB030479R0512

PROSOFT RLX2-IHW-E

P0926HW FOXBORO

A-B PLC communication module 1747-L542

 

Reviews

There are no reviews yet.

Be the first to review “WOODWARD 5464-213 Digital Microprocessor Controller”

Your email address will not be published. Required fields are marked *