WOODWARD Peak 150 Digital Steam Turbine Control 9905-867

Sale!

WOODWARD Peak 150 Digital Steam Turbine Control 9905-867

¥454.00

Description


Many products have not been listed yet. For more products, please contact us

  If the product model is inconsistent with the displayed image, the model shall prevail. Please contact us for specific product images, and we will arrange for photos to be taken and confirmed in the warehouse

  We have 16 shared warehouses worldwide, so sometimes it may take several hours to accurately return to you. We apologize for any inconvenience caused. Of course, we will respond to your concerns as soon as possible.


The API611 steam turbine controller designed for small single valve/single valve rack industrial steam turbines. The cost effective configurable controller includes specifically designed algorithms and logic to start, stop, control, and protect small industrial steam turbines or turboexpanders driving compressors, pumps, or industrial fans. This Peak150 model comes in a 120VAC/DC, MODBUS, NEMA4X enclosure for steam turbine digital governor control with overspeed protection.


  FEATURES & FUNCTIONALITY

Inputs

  Magnetic Pickup Inputs (2):

Two identical inputs, high-signal-selected

Minimum input voltage 1 Vrms, minimum frequency 200 Hz, maximum frequency 15 kHz

  Analog Input (1):

Remote Speed Setting signal (4–20 mA or 1–5 Vdc, internal jumper selectable)

Discrete Inputs (8)

Remote (isolated, 5–28 Vdc)


  Options:

Raise speed

Lower speed

Emergency stop

Alarm reset

Remote speed set enable

Start

Idle/minimum governor

Select high dynamics or overspeed test

Outputs 


 Analog Outputs (2):

Actual speed output (scalable, 4–20/0–1 mA)

Configurable readout (scalable, 4–20/0–1 mA)


  Options:

Actual speed

Speed setpoint

Actuator output

Remote speed setpoint

Valve ramp value

Actuator Output (1)

4–20 or 0–200 mA (internal jumper selectable)


  Relay Outputs (4)

Control model 9905-144 is a speed control from Woodward’s 2301A series. This control is a low-voltage and forward-acting model. The setting of the actuator potentiometer for voltage is different on the forward acting control than on the reverse; the forward acting controls actuator voltage should be set ten percent higher than whatever the voltage for the rated speed was read at. In reference to the rated speed, preliminary settings for this potentiometer should be set to the absolute minimum; this means the potentiometer will be sitting fully counterclockwise on your control.

9907-838
 

If using an SPM (speed and phase matching) synchronizer, connect the wires to terminals twenty-five and twenty-six, the positive lead must be connected to terminal twenty-five, and the negative lead must be connected to terminal twenty-six, then using a shielded wire, connect to terminal twenty-seven. It is important to note that the shield should never be connected to the synchronizer. Please advise that the SPM synchronizer is not required for the 9905-144 control to function it is only optional.

 

Be advised that during the operation of the prime mover and the 9905-144 control, if an error occurs, take caution and make an emergency shutdown of the prime mover; doing so prevents property damage and runaway of the prime mover. It is highly recommended that with the operation of the prime mover and control, an external overspeed shutdown device should be used to assist with the shutdown if the prime mover begins to overspeed; overspeeding of the prime mover can result in a runaway and injury.https://www.weikunfadacai1.com/


Frequently Asked Questions about 9905-144

What are the elements needed alongside the 9905-144 control when operating a prime mover?

Other than the 9905-144, when operating a prime mover, a speed-sensing device, such as an MPU, is required, along with an external power source that operates on 10 to 40 VDC or 12 W, and a proportional actuator that will be used to position the steam- or fuel-metering device. All of these elements together allow for the attached prime mover to be controlled without any potential faults or errors occurring.

What is the difference between this model, which is forward acting compared, to a reverse-acting model such as 9905-146?

The main difference between forward-acting and reverse-acting models is that reverse-acting controls can operate additional Woodward models, such as EGB governors or actuators. Another main difference between the two systems is that reverse-acting systems require more fuel when the current on the actuator decreases; if a complete loss of signal occurs on the actuator, the actuator will automatically turn to full fuel. Due to limited information, it can be difficult to find out how the forward-acting models operate, although it should be fairly self-explanatory leading to the lack of information.

 Model recommendation:

WOODWARD 9905-969

Reviews

There are no reviews yet.

Be the first to review “WOODWARD Peak 150 Digital Steam Turbine Control 9905-867”

Your email address will not be published. Required fields are marked *